<!DOCTYPE html>
<html class="client-nojs vector-feature-night-mode-disabled vector-feature-language-in-header-enabled vector-feature-language-in-main-page-header-disabled vector-feature-page-tools-pinned-disabled vector-feature-toc-pinned-clientpref-1 vector-feature-main-menu-pinned-disabled vector-feature-limited-width-clientpref-1 vector-feature-limited-width-content-enabled vector-feature-custom-font-size-clientpref-1 vector-feature-appearance-pinned-clientpref-1 vector-sticky-header-enabled" lang="en" dir="ltr"><head>
<meta charset="UTF-8">
<title>Common-path interferometer</title>
<meta name="viewport" content="width=device-width, initial-scale=1.0">
<link rel="canonical" href="https://en.wikipedia.org/wiki/Common-path_interferometer"> <link href="./mw/ext.cite.styles.css" rel="stylesheet" type="text/css">
<link href="./mw/skins.vector.icons.css" rel="stylesheet" type="text/css">
<link href="./mw/skins.vector.search.codex.styles.css" rel="stylesheet" type="text/css">
<link href="./mw/skins.vector.styles.css" rel="stylesheet" type="text/css">
<link href="./mw/user.styles.css" rel="stylesheet" type="text/css">
<meta name="ResourceLoaderDynamicStyles" content="">
<link rel="stylesheet" type="text/css" href="./mw/site.styles.css">
<link rel="stylesheet" type="text/css" href="./mw/noscript.css">
<link rel="stylesheet" type="text/css" href="./footer.css">
<link rel="stylesheet" type="text/css" href="./vector-2022.css">
</head>
<body class="skin--responsive skin-vector skin-vector-search-vue mediawiki ltr sitedir-ltr mw-hide-empty-elt ns-0 ns-subject page-Common-path_interferometer rootpage-Common-path_interferometer skin-vector-2022 action-view">
<div class="mw-page-container">
<div class="mw-page-container-inner">
<div class="mw-content-container">
<main id="content" class="mw-body">
<header class="mw-body-header vector-page-titlebar">
<h1 id="firstHeading" class="firstHeading mw-first-heading">
<span id="openzim-page-title" class="mw-page-title-main"><span class="mw-page-title-main">Common-path interferometer</span></span>
</h1>
</header>
<a id="top"></a>
<div id="bodyContent" class="vector-body ve-init-mw-desktopArticleTarget-targetContainer" aria-labelledby="firstHeading" data-mw-ve-target-container="">
<div id="mw-content-text" class="mw-body-content mw-content-ltr" lang="en" dir="ltr"><div class="mw-content-ltr mw-parser-output" lang="en" dir="ltr"><p>A <b>common-path interferometer</b> is a class of <a href="Interferometer" class="mw-redirect" title="Interferometer">interferometers</a> in which the reference beam and sample beams travel along the same path. Examples include the <a href="Sagnac_interferometer" class="mw-redirect" title="Sagnac interferometer">Sagnac interferometer</a>, <a href="Zernike_phase-contrast_interferometer" class="mw-redirect" title="Zernike phase-contrast interferometer">Zernike phase-contrast interferometer</a>, and the <a href="Point_diffraction_interferometer" title="Point diffraction interferometer">point diffraction interferometer</a>. A common-path interferometer is generally more robust to environmental vibrations than a "double-path interferometer" such as the <a href="Michelson_interferometer" title="Michelson interferometer">Michelson interferometer</a> or the <a href="Mach%E2%80%93Zehnder_interferometer" title="Mach–Zehnder interferometer">Mach–Zehnder interferometer</a>.<sup id="cite_ref-Vakhtin2003_1-0" class="reference"><a href="#cite_note-Vakhtin2003-1"><span class="cite-bracket">[</span>1<span class="cite-bracket">]</span></a></sup> Although travelling along the same path, the reference and sample beams may travel along opposite directions, or they may travel along the same direction but with the same or different polarization.
</p><p>Double-path interferometers are highly sensitive to phase shifts or length changes between the reference and sample arms. Because of this, double-path interferometers have found wide use in science and industry for the measurement of small displacements,<sup id="cite_ref-2" class="reference"><a href="#cite_note-2"><span class="cite-bracket">[</span>2<span class="cite-bracket">]</span></a></sup> refractive-index changes,<sup id="cite_ref-3" class="reference"><a href="#cite_note-3"><span class="cite-bracket">[</span>3<span class="cite-bracket">]</span></a></sup> surface irregularities and the like. There are applications, however, in which sensitivity to relative displacement or refractive-index differences between reference and sample paths is not desirable; alternatively, one may be interested in the measurement of some other property.
</p>
<meta property="mw:PageProp/toc">
<div class="mw-heading mw-heading2"><h2 id="Selected_examples">Selected examples</h2></div>
<div class="mw-heading mw-heading3"><h3 id="Sagnac">Sagnac</h3></div>
<style data-mw-deduplicate="TemplateStyles:r1236090951">
/* start https://en.wikipedia.org/ */
.mw-parser-output .hatnote{font-style:italic}.mw-parser-output div.hatnote{padding-left:1.6em;margin-bottom:0.5em}.mw-parser-output .hatnote i{font-style:normal}.mw-parser-output .hatnote+link+.hatnote{margin-top:-0.5em}@media print{body.ns-0 .mw-parser-output .hatnote{display:none!important}}
/* end https://en.wikipedia.org/ */
</style><div role="note" class="hatnote navigation-not-searchable">Main article: <a href="Sagnac_interferometer" class="mw-redirect" title="Sagnac interferometer">Sagnac interferometer</a></div>
<p>Sagnac interferometers are totally unsuited for measuring lengths or length changes. In a Sagnac interferometer, both beams emerging from the beamsplitter simultaneously go around all four sides of a rectangle in opposite directions and recombine at the original beamsplitter. The result is that a Sagnac interferometer is, to first order, completely insensitive to any movement of its optical components. Indeed, in order to make the Sagnac interferometer useful for measuring phase changes, the beams of the interferometer must be separated slightly so that they no longer follow a perfectly common path. Even with a slight beam separation, Sagnac interferometers offer excellent contrast and fringe stability.<sup id="cite_ref-Optics471ASagnac_4-0" class="reference"><a href="#cite_note-Optics471ASagnac-4"><span class="cite-bracket">[</span>4<span class="cite-bracket">]</span></a></sup> Two basic topologies of the Sagnac interferometer are possible, differing in whether there are an even or odd number of reflections in each path. In a Sagnac interferometer with an odd number of reflections, such as the one illustrated, the wavefronts of the oppositely traveling beams are laterally inverted with respect to each other over most of the light path, so the topology is not strictly common-path.<sup id="cite_ref-Hariharan2007_5-0" class="reference"><a href="#cite_note-Hariharan2007-5"><span class="cite-bracket">[</span>5<span class="cite-bracket">]</span></a></sup>
</p><p>The best known use of the Sagnac interferometer lies in its sensitivity to rotation. The first accounts of the effects of rotation on this form of interferometer were published in 1913 by Georges Sagnac, who mistakenly believed that his ability to detect a "whirling of the ether" disproved relativity theory.<sup id="cite_ref-Anderson1994_6-0" class="reference"><a href="#cite_note-Anderson1994-6"><span class="cite-bracket">[</span>6<span class="cite-bracket">]</span></a></sup> The sensitivity of present-day Sagnac interferometers far exceeds that of Sagnac's original arrangement. The sensitivity to rotation is proportional to the area circumscribed by the counter-rotating beams, and <a href="Fibre_optic_gyroscope" class="mw-redirect" title="Fibre optic gyroscope">fibre optic gyroscopes</a>, present-day descendants of the Sagnac interferometer, use thousands of loops of optical fibre rather than mirrors, such that even small to medium-sized units easily detect the rotation of the Earth.<sup id="cite_ref-Lin1979_7-0" class="reference"><a href="#cite_note-Lin1979-7"><span class="cite-bracket">[</span>7<span class="cite-bracket">]</span></a></sup> <a href="Ring_laser_gyroscope" title="Ring laser gyroscope">Ring laser gyroscopes</a> (not illustrated) are another form of Sagnac rotation sensor that have important applications in inertial guidance systems.<sup id="cite_ref-Anderson1994_6-1" class="reference"><a href="#cite_note-Anderson1994-6"><span class="cite-bracket">[</span>6<span class="cite-bracket">]</span></a></sup>
</p><p>Because of their exceptional contrast and fringe stability, interferometers using the Sagnac configuration played an important role in experiments leading to Einstein's discovery of <a href="Special_relativity" title="Special relativity">special relativity</a>, and in the subsequent defense of relativity against theoretical and experimental challenges. For example, one year before their <a href="Michelson%E2%80%93Morley_experiment" title="Michelson–Morley experiment">famous experiment of 1887</a>, Michelson and Morley (1886) performed a repeat of the <a href="Fizeau_experiment#Repetitions" title="Fizeau experiment">Fizeau experiment</a> of 1851, replacing Fizeau's setup with an even-reflection Sagnac interferometer of such high stability, that even placing a lighted match in the light path did not cause artifactual fringe displacement.<sup id="cite_ref-mich_8-0" class="reference"><a href="#cite_note-mich-8"><span class="cite-bracket">[</span>8<span class="cite-bracket">]</span></a></sup> In 1935, <a href="Hammar_experiment" title="Hammar experiment">Gustaf Wilhelm Hammar</a> disproved a theoretical challenge to special relativity that attempted to explain away the null results of Michelson–Morley–type experiments as being mere artifact of <a href="Aether-dragging" class="mw-redirect" title="Aether-dragging">aether-dragging</a>, using an odd-reflection Sagnac interferometer. He could operate this interferometer in the open, on a high hilltop with no temperature control, yet still achieve readings of 1/10 fringe accuracy.<sup id="cite_ref-ham_9-0" class="reference"><a href="#cite_note-ham-9"><span class="cite-bracket">[</span>9<span class="cite-bracket">]</span></a></sup><sup id="cite_ref-rob_10-0" class="reference"><a href="#cite_note-rob-10"><span class="cite-bracket">[</span>10<span class="cite-bracket">]</span></a></sup>
</p>
<div class="mw-heading mw-heading3"><h3 id="Point_diffraction">Point diffraction</h3></div>
<div role="note" class="hatnote navigation-not-searchable">Main article: <a href="Point_diffraction_interferometer" title="Point diffraction interferometer">Point diffraction interferometer</a></div>
<p>Another common-path interferometer useful in lens testing and fluid flow diagnostics is the <a href="Point_diffraction_interferometer" title="Point diffraction interferometer">point diffraction interferometer</a> (PDI), invented by Linnik in 1933.<sup id="cite_ref-Millerd2004_11-0" class="reference"><a href="#cite_note-Millerd2004-11"><span class="cite-bracket">[</span>11<span class="cite-bracket">]</span></a></sup><sup id="cite_ref-Mercer1996_12-0" class="reference"><a href="#cite_note-Mercer1996-12"><span class="cite-bracket">[</span>12<span class="cite-bracket">]</span></a></sup> The reference beam is generated by diffraction from a small pinhole, about half the diameter of the <a href="Airy_disk" title="Airy disk">Airy disk</a>, in a semitransparent plate. Fig. 1 illustrates an aberrated wavefront focused onto the pinhole. The diffracted reference beam and the transmitted test wave interfere to form fringes. The common-path design of the PDI brings to it a number of important advantages. (1) Only a single laser path is required rather than the two paths required by the Mach-Zehnder or Michelson designs. This advantage can be very important in large interferometric setups such as in wind tunnels that have long optical paths through turbulent media. (2) The common-path design uses fewer optical components than double path designs, making alignment much easier, as well as reducing cost, size, and weight, especially for large setups.<sup id="cite_ref-Ferraro2007_13-0" class="reference"><a href="#cite_note-Ferraro2007-13"><span class="cite-bracket">[</span>13<span class="cite-bracket">]</span></a></sup> (3) While the accuracy of a double path design is dependent on the precision with which the reference element is figured, careful design enables the generated reference beam of the PDI to be of guaranteed precision.<sup id="cite_ref-Naulleau1999_14-0" class="reference"><a href="#cite_note-Naulleau1999-14"><span class="cite-bracket">[</span>14<span class="cite-bracket">]</span></a></sup> A disadvantage is that the amount of light getting through the pinhole depends on how well the light can be focused onto the pinhole. If the incident wavefront is severely aberrated, very little light may get through.<sup id="cite_ref-Malacara2006_15-0" class="reference"><a href="#cite_note-Malacara2006-15"><span class="cite-bracket">[</span>15<span class="cite-bracket">]</span></a></sup> The PDI has seen use in various <a href="Adaptive_optics" title="Adaptive optics">adaptive optics</a> applications.<sup id="cite_ref-Love1995_16-0" class="reference"><a href="#cite_note-Love1995-16"><span class="cite-bracket">[</span>16<span class="cite-bracket">]</span></a></sup><sup id="cite_ref-Paterson2007_17-0" class="reference"><a href="#cite_note-Paterson2007-17"><span class="cite-bracket">[</span>17<span class="cite-bracket">]</span></a></sup>
</p>
<div class="mw-heading mw-heading3"><h3 id="Lateral_shearing">Lateral shearing</h3></div>
<div role="note" class="hatnote navigation-not-searchable">Main article: <a href="Shearing_interferometer" title="Shearing interferometer">Shearing interferometer</a></div>
<p>Lateral shearing interferometry is a self-referencing method of wavefront sensing. Instead of comparing a wavefront with a separate path reference wavefront, lateral shearing interferometry interferes a wavefront with a shifted version of itself. As a result, it is sensitive to the slope of a wavefront, not the wavefront shape <i>per se</i>. The illustrated plane parallel plate interferometer has unequal path lengths for the test and reference beams; because of this, it must be used with highly monochromatic (laser) light. It is normally used without any coating on either surface, so as to minimize ghost reflections. An aberrated wavefront from a lens under test is reflected from the front and back of the plate to form the interference pattern. Variations on this basic design allow testing of mirrors. Other forms of lateral shearing interferometer, based on the <a href="Jamin_interferometer" title="Jamin interferometer">Jamin</a>, <a href="Michelson_interferometer" title="Michelson interferometer">Michelson</a>, <a href="Mach%E2%80%93Zehnder_interferometer" title="Mach–Zehnder interferometer">Mach–Zehnder</a>, and other interferometer designs, have compensated paths and may be used with white light.<sup id="cite_ref-Strojnik2006_18-0" class="reference"><a href="#cite_note-Strojnik2006-18"><span class="cite-bracket">[</span>18<span class="cite-bracket">]</span></a></sup> Besides optical testing, applications of lateral shearing interferometry have included thin film analysis, mass and thermal diffusion in transparent materials, refractive index and gradient of refractive index measurement, collimation testing, and adaptive optics.<sup id="cite_ref-19" class="reference"><a href="#cite_note-19"><span class="cite-bracket">[</span>19<span class="cite-bracket">]</span></a></sup><sup id="cite_ref-Ribak_20-0" class="reference"><a href="#cite_note-Ribak-20"><span class="cite-bracket">[</span>20<span class="cite-bracket">]</span></a></sup> Shearing interferometers, a general framework which includes the lateral shearing, Hartmann, <a href="Shack%E2%80%93Hartmann_wavefront_sensor" title="Shack–Hartmann wavefront sensor">Shack–Hartmann</a>, rotational shearing, folding shearing, and <a href="Aperture_masking_interferometry" title="Aperture masking interferometry">aperture masking</a> interferometers, are used in most of the wavefront sensors industrially developed.<sup id="cite_ref-21" class="reference"><a href="#cite_note-21"><span class="cite-bracket">[</span>21<span class="cite-bracket">]</span></a></sup>
</p>
<div class="mw-heading mw-heading3"><h3 id="Fresnel's_biprism">Fresnel's biprism</h3></div>
<p>From the modern perspective, the result of <a href="Young's_interference_experiment" title="Young's interference experiment">Young's double slit experiment</a> (see Fig. 2) clearly points towards the wave nature of light, but such was not the case in the early 1800s. Newton, after all, had observed what are now recognized as diffraction phenomena, and wrote on them in his Third Book of Optics,<sup id="cite_ref-NewtonOpticks_22-0" class="reference"><a href="#cite_note-NewtonOpticks-22"><span class="cite-bracket">[</span>22<span class="cite-bracket">]</span></a></sup> interpreting them in terms of his <a href="Corpuscular_theory_of_light" title="Corpuscular theory of light">corpuscular theory of light</a>. Young's contemporaries raised objections that his results could simply represent diffraction effects from the edges of the slits, no different in principle than the fringes that Newton had previously observed. <a href="Augustin_Fresnel" class="mw-redirect" title="Augustin Fresnel">Augustin Fresnel</a>, who supported the wave theory, performed a series of experiments to demonstrate interference effects that could not be simply explained away as being the result of edge diffraction. The most notable of these was his use of a <a href="Biprism" class="mw-redirect" title="Biprism">biprism</a> to create two virtual interfering sources by refraction.
</p><p>An electron version of the Fresnel biprism is used in <a href="Electron_holography" title="Electron holography">electron holography</a>, an imaging technique that photographically records the electron interference pattern of an object. The hologram can then be illuminated by a laser resulting in a greatly magnified image of the original object, although the current preference is for numerical reconstruction of the holograms.<sup id="cite_ref-23" class="reference"><a href="#cite_note-23"><span class="cite-bracket">[</span>23<span class="cite-bracket">]</span></a></sup> This technique was developed to enable greater resolution in electron microscopy than is possible using conventional imaging techniques. The resolution of conventional electron microscopy is not limited by electron wavelength, but by the large aberrations of electron lenses.<sup id="cite_ref-Tonomura1999_24-0" class="reference"><a href="#cite_note-Tonomura1999-24"><span class="cite-bracket">[</span>24<span class="cite-bracket">]</span></a></sup>
</p><p>Fig. 3 shows the basic arrangement of an interference electron microscope. The electron biprism consists of a fine, positively charged electric filament (represented as a dot in the figure) bracketed by two plate electrodes at ground potential. The filament, generally not more than 1 μm in diameter, is usually a gold-coated quartz fiber. By placing the specimen off-axis in the electron beam, the diffracted specimen wavefront and the reference wavefront combine to create the hologram.
</p>
<div class="mw-heading mw-heading3"><h3 id="Zero-area_Sagnac">Zero-area Sagnac</h3></div>
<p>The <a href="LIGO" title="LIGO">Laser Interferometer Gravitational-Wave Observatory</a> (LIGO) consisted of two 4-km <a href="Fabry%E2%80%93P%C3%A9rot_interferometer" title="Fabry–Pérot interferometer">Michelson–Fabry–Pérot interferometers</a>, and operated at a power level of about 100 watts of laser power at the beam splitter. A currently ongoing upgrade to Advanced LIGO will require several kilowatts of laser power, and scientists will need to contend with thermal distortion, frequency variation of the lasers, mirror displacement and thermally induced <a href="Birefringence" title="Birefringence">birefringence</a>.
</p><p>A variety of competing optical systems are being explored for third generation enhancements beyond Advanced LIGO. One of these competing topologies has been the zero-area Sagnac design. As noted above, Sagnac interferometers are, to first order, insensitive to any static or low-frequency displacement of their optical components, nor are the fringes affected by minor frequency variation in the lasers or birefringence. A zero-area variant of the Sagnac interferometer has been proposed for third generation LIGO. Fig. 1 shows how by directing the light through two loops of opposite sense, an effective area of zero is obtained. This variant of the Sagnac interferometer is hence insensitive to rotation or low frequency drift of its optical components, while maintaining a high sensitivity to transient events of astronomical interest.<sup id="cite_ref-Sun1996_25-0" class="reference"><a href="#cite_note-Sun1996-25"><span class="cite-bracket">[</span>25<span class="cite-bracket">]</span></a></sup> However, many considerations are involved in the choice of an optical system, and despite the zero-area Sagnac's superiority in certain areas, there is as yet no consensus choice of optical system for third generation LIGO.<sup id="cite_ref-Friese2009_26-0" class="reference"><a href="#cite_note-Friese2009-26"><span class="cite-bracket">[</span>26<span class="cite-bracket">]</span></a></sup><sup id="cite_ref-Eberle2010_27-0" class="reference"><a href="#cite_note-Eberle2010-27"><span class="cite-bracket">[</span>27<span class="cite-bracket">]</span></a></sup>
</p>
<div class="mw-heading mw-heading3"><h3 id="Scatterplate">Scatterplate</h3></div>
<p>A common path alternative to the <a href="Twyman%E2%80%93Green_interferometer" title="Twyman–Green interferometer">Twyman–Green interferometer</a> is the scatterplate interferometer,<sup id="cite_ref-UACOS_28-0" class="reference"><a href="#cite_note-UACOS-28"><span class="cite-bracket">[</span>28<span class="cite-bracket">]</span></a></sup> invented by J.M. Burch in 1953.<sup id="cite_ref-Burch1953_29-0" class="reference"><a href="#cite_note-Burch1953-29"><span class="cite-bracket">[</span>29<span class="cite-bracket">]</span></a></sup> The Twyman–Green interferometer, a double path interferometer, is a variant of the Michelson interferometer that is commonly used to test the precision of optical surfaces and lenses.<sup id="cite_ref-SPIETwymanGreen_30-0" class="reference"><a href="#cite_note-SPIETwymanGreen-30"><span class="cite-bracket">[</span>30<span class="cite-bracket">]</span></a></sup><sup id="cite_ref-Optics4EngineersTwyman_31-0" class="reference"><a href="#cite_note-Optics4EngineersTwyman-31"><span class="cite-bracket">[</span>31<span class="cite-bracket">]</span></a></sup> Since reference and sample paths are divergent, this form of interferometer is extremely sensitive to vibration and to atmospheric turbulence in the light paths, both of which interfere with the optical measurements. Precision measurements of an optical surface are also extremely dependent on the quality of the auxiliary optics.
</p><p>Because the scatterplate interferometer is a common-path interferometer, the reference and test paths are automatically matched so that a zero order fringe can be easily obtained even with white light. It is relatively insensitive to vibration and turbulence, and the quality of the auxiliary optics is not as critical as in a Twyman-Green setup.<sup id="cite_ref-UACOS_28-1" class="reference"><a href="#cite_note-UACOS-28"><span class="cite-bracket">[</span>28<span class="cite-bracket">]</span></a></sup> Fringe contrast, however, is lower, and a characteristic hotspot may make the scatterplate interferometer unsuitable for various purposes. A variety of other common-path interferometers useful for optical testing have been described.<sup id="cite_ref-Malacara2006_15-1" class="reference"><a href="#cite_note-Malacara2006-15"><span class="cite-bracket">[</span>15<span class="cite-bracket">]</span></a></sup><sup id="cite_ref-Dyson1957_32-0" class="reference"><a href="#cite_note-Dyson1957-32"><span class="cite-bracket">[</span>32<span class="cite-bracket">]</span></a></sup>
</p><p>Fig. 1 shows the interferometer set up to test a spherical mirror. A scatterplate is set near the center of curvature of the mirror under test. This plate has a pattern of tiny opaque patches which are arranged on the plate with inversion symmetry but which are otherwise random in shape and distribution. (1) A certain fraction of the light passes directly through the scatterplate, is reflected by the mirror, but then is scattered as it encounters the scatterplate for the second time. This <i>direct-scattered</i> light forms the reference beam. (2) A certain fraction of the light is scattered as it passes through the scatterplate, is reflected by the mirror, but then passes directly through the scatterplate as it encounters the scatterplate for the second time. This <i>scattered-direct</i> light forms the test beam, which combines with the reference beam to form interference fringes. (3) A certain fraction of the light passes directly through the scatterplate on both of its encounters. This <i>direct-direct</i> light generates a small, undesirable hotspot. (4) A certain fraction of the light is scattered on both encounters with the scatterplate. This <i>scattered-scattered</i> light lowers the overall contrast of the interference pattern.<sup id="cite_ref-Wyatt2002_33-0" class="reference"><a href="#cite_note-Wyatt2002-33"><span class="cite-bracket">[</span>33<span class="cite-bracket">]</span></a></sup>
</p>
<div class="mw-heading mw-heading3"><h3 id="Bath_Interferometer">Bath Interferometer</h3></div>
<div role="note" class="hatnote navigation-not-searchable">Main article: <a href="Bath_interferometer_(common_path)" title="Bath interferometer (common path)">Bath interferometer (common path)</a></div>
<p>The Bath Interferometer (Fig. 4) can be used to test telescope mirrors. It usually consists of a beam splitter, an optical flat, a biconvex diverger of short focal length and a light source such as a semiconductor laser.<sup id="cite_ref-34" class="reference"><a href="#cite_note-34"><span class="cite-bracket">[</span>34<span class="cite-bracket">]</span></a></sup>
</p>
<div class="mw-heading mw-heading2"><h2 id="Other_configurations">Other configurations</h2></div>
<p>Other common-path interferometer configurations have been described in the literature, such as the double-focus interferometer and the Saunders's prism interferometer,<sup id="cite_ref-Malacara2006_15-2" class="reference"><a href="#cite_note-Malacara2006-15"><span class="cite-bracket">[</span>15<span class="cite-bracket">]</span></a></sup> and many others. Common-path interferometers have proven useful in a wide variety of applications including optical coherence tomography,<sup id="cite_ref-Vakhtin2003_1-1" class="reference"><a href="#cite_note-Vakhtin2003-1"><span class="cite-bracket">[</span>1<span class="cite-bracket">]</span></a></sup> digital holography,<sup id="cite_ref-Mico2006_35-0" class="reference"><a href="#cite_note-Mico2006-35"><span class="cite-bracket">[</span>35<span class="cite-bracket">]</span></a></sup> and the measurement of phase delays.<sup id="cite_ref-Márquez2001_36-0" class="reference"><a href="#cite_note-Márquez2001-36"><span class="cite-bracket">[</span>36<span class="cite-bracket">]</span></a></sup> Their relative resilience to environmental vibration is a common outstanding feature, and they can sometimes be used when no reference beam is available; however, depending on their topology, their interference patterns may be more complicated to interpret than those generated by double path interferometers.
</p>
<div class="mw-heading mw-heading2"><h2 id="See_also">See also</h2></div>
<ul><li><a href="Double-path_interferometer" class="mw-redirect" title="Double-path interferometer">Double-path interferometer</a></li></ul>
<div class="mw-heading mw-heading2"><h2 id="References">References</h2></div>
<style data-mw-deduplicate="TemplateStyles:r1239543626">
/* start https://en.wikipedia.org/ */
.mw-parser-output .reflist{margin-bottom:0.5em;list-style-type:decimal}@media screen{.mw-parser-output .reflist{font-size:90%}}.mw-parser-output .reflist .references{font-size:100%;margin-bottom:0;list-style-type:inherit}.mw-parser-output .reflist-columns-2{column-width:30em}.mw-parser-output .reflist-columns-3{column-width:25em}.mw-parser-output .reflist-columns{margin-top:0.3em}.mw-parser-output .reflist-columns ol{margin-top:0}.mw-parser-output .reflist-columns li{page-break-inside:avoid;break-inside:avoid-column}.mw-parser-output .reflist-upper-alpha{list-style-type:upper-alpha}.mw-parser-output .reflist-upper-roman{list-style-type:upper-roman}.mw-parser-output .reflist-lower-alpha{list-style-type:lower-alpha}.mw-parser-output .reflist-lower-greek{list-style-type:lower-greek}.mw-parser-output .reflist-lower-roman{list-style-type:lower-roman}
/* end https://en.wikipedia.org/ */
</style><div class="reflist">
<div class="mw-references-wrap mw-references-columns"><ol class="references">
<li id="cite_note-Vakhtin2003-1"><span class="mw-cite-backlink">^ <a href="#cite_ref-Vakhtin2003_1-0"><sup><i><b>a</b></i></sup></a> <a href="#cite_ref-Vakhtin2003_1-1"><sup><i><b>b</b></i></sup></a></span> <span class="reference-text"><style data-mw-deduplicate="TemplateStyles:r1238218222">
/* start https://en.wikipedia.org/ */
.mw-parser-output cite.citation{font-style:inherit;word-wrap:break-word}.mw-parser-output .citation q{quotes:"\"""\"""'""'"}.mw-parser-output .citation:target{background-color:rgba(0,127,255,0.133)}.mw-parser-output .id-lock-free.id-lock-free a{background:url("./mw/Lock-green.svg")right 0.1em center/9px no-repeat}.mw-parser-output .id-lock-limited.id-lock-limited a,.mw-parser-output .id-lock-registration.id-lock-registration a{background:url("./mw/Lock-gray-alt-2.svg")right 0.1em center/9px no-repeat}.mw-parser-output .id-lock-subscription.id-lock-subscription a{background:url("./mw/Lock-red-alt-2.svg")right 0.1em center/9px no-repeat}.mw-parser-output .cs1-ws-icon a{background:url("./mw/Wikisource-logo.svg")right 0.1em center/12px no-repeat}body:not(.skin-timeless):not(.skin-minerva) .mw-parser-output .id-lock-free a,body:not(.skin-timeless):not(.skin-minerva) .mw-parser-output .id-lock-limited a,body:not(.skin-timeless):not(.skin-minerva) .mw-parser-output .id-lock-registration a,body:not(.skin-timeless):not(.skin-minerva) .mw-parser-output .id-lock-subscription a,body:not(.skin-timeless):not(.skin-minerva) .mw-parser-output .cs1-ws-icon a{background-size:contain;padding:0 1em 0 0}.mw-parser-output .cs1-code{color:inherit;background:inherit;border:none;padding:inherit}.mw-parser-output .cs1-hidden-error{display:none;color:var(--color-error,#d33)}.mw-parser-output .cs1-visible-error{color:var(--color-error,#d33)}.mw-parser-output .cs1-maint{display:none;color:#085;margin-left:0.3em}.mw-parser-output .cs1-kern-left{padding-left:0.2em}.mw-parser-output .cs1-kern-right{padding-right:0.2em}.mw-parser-output .citation .mw-selflink{font-weight:inherit}@media screen{.mw-parser-output .cs1-format{font-size:95%}html.skin-theme-clientpref-night .mw-parser-output .cs1-maint{color:#18911f}}@media screen and (prefers-color-scheme:dark){html.skin-theme-clientpref-os .mw-parser-output .cs1-maint{color:#18911f}}
/* end https://en.wikipedia.org/ */
</style><cite id="CITEREFVakhtinKane,_D._J.Wood,_W._R.Peterson,_K._A.2003" class="citation journal cs1">Vakhtin, A. B.; Kane, D. J.; Wood, W. R.; Peterson, K. A. (2003). <a rel="nofollow" class="external text" href="http://swsciences.com/research/papers/Vakhtin_2003_ApplOpt_CommonPathInterferometer.pdf">"Common-path interferometer for frequency-domain optical coherence tomography"</a> <span class="cs1-format">(PDF)</span>. <i>Applied Optics</i>. <b>42</b> (34): <span class="nowrap">6953–</span>6957. <a href="Bibcode_(identifier)" class="mw-redirect" title="Bibcode (identifier)">Bibcode</a>:<a rel="nofollow" class="external text" href="https://ui.adsabs.harvard.edu/abs/2003ApOpt..42.6953V">2003ApOpt..42.6953V</a>. <a href="Doi_(identifier)" class="mw-redirect" title="Doi (identifier)">doi</a>:<a rel="nofollow" class="external text" href="https://doi.org/10.1364%2FAO.42.006953">10.1364/AO.42.006953</a>. <a href="PMID_(identifier)" class="mw-redirect" title="PMID (identifier)">PMID</a> <a rel="nofollow" class="external text" href="https://pubmed.ncbi.nlm.nih.gov/14661810">14661810</a><span class="reference-accessdate">. Retrieved <span class="nowrap">29 March</span> 2012</span>.</cite></span>
</li>
<li id="cite_note-2"><span class="mw-cite-backlink"><b><a href="#cite_ref-2">^</a></b></span> <span class="reference-text"><cite id="CITEREFLinChenChen2011" class="citation journal cs1">Lin, Jiun-You; Chen, Kun-Huang; Chen, Jing-Heng (2011-07-01). "Measurement of small displacement based on surface plasmon resonance heterodyne interferometry". <i>Optics and Lasers in Engineering</i>. <b>49</b> (7): <span class="nowrap">811–</span>815. <a href="Bibcode_(identifier)" class="mw-redirect" title="Bibcode (identifier)">Bibcode</a>:<a rel="nofollow" class="external text" href="https://ui.adsabs.harvard.edu/abs/2011OptLE..49..811L">2011OptLE..49..811L</a>. <a href="Doi_(identifier)" class="mw-redirect" title="Doi (identifier)">doi</a>:<a rel="nofollow" class="external text" href="https://doi.org/10.1016%2Fj.optlaseng.2011.03.005">10.1016/j.optlaseng.2011.03.005</a>. <a href="ISSN_(identifier)" class="mw-redirect" title="ISSN (identifier)">ISSN</a> <a rel="nofollow" class="external text" href="https://search.worldcat.org/issn/0143-8166">0143-8166</a>.</cite></span>
</li>
<li id="cite_note-3"><span class="mw-cite-backlink"><b><a href="#cite_ref-3">^</a></b></span> <span class="reference-text"><cite id="CITEREFNgLooWuKong2013" class="citation journal cs1">Ng, Siu Pang; Loo, Fong Chuen; Wu, Shu Yuen; Kong, Siu Kai; Wu, Chi Man Lawrence; Ho, Ho Pui (2013-08-26). <a rel="nofollow" class="external text" href="https://doi.org/10.1364%2FOE.21.020268">"Common-path spectral interferometry with temporal carrier for highly sensitive surface plasmon resonance sensing"</a>. <i>Optics Express</i>. <b>21</b> (17): <span class="nowrap">20268–</span>20273. <a href="Bibcode_(identifier)" class="mw-redirect" title="Bibcode (identifier)">Bibcode</a>:<a rel="nofollow" class="external text" href="https://ui.adsabs.harvard.edu/abs/2013OExpr..2120268N">2013OExpr..2120268N</a>. <a href="Doi_(identifier)" class="mw-redirect" title="Doi (identifier)">doi</a>:<span class="id-lock-free" title="Freely accessible"><a rel="nofollow" class="external text" href="https://doi.org/10.1364%2FOE.21.020268">10.1364/OE.21.020268</a></span>. <a href="ISSN_(identifier)" class="mw-redirect" title="ISSN (identifier)">ISSN</a> <a rel="nofollow" class="external text" href="https://search.worldcat.org/issn/1094-4087">1094-4087</a>. <a href="PMID_(identifier)" class="mw-redirect" title="PMID (identifier)">PMID</a> <a rel="nofollow" class="external text" href="https://pubmed.ncbi.nlm.nih.gov/24105572">24105572</a>.</cite></span>
</li>
<li id="cite_note-Optics471ASagnac-4"><span class="mw-cite-backlink"><b><a href="#cite_ref-Optics471ASagnac_4-0">^</a></b></span> <span class="reference-text"><cite class="citation web cs1"><a rel="nofollow" class="external text" href="http://www.optics.arizona.edu/opti471a/Sagnac/The%20Sagnac%20Interferometer.pdf">"The Sagnac Interferometer"</a> <span class="cs1-format">(PDF)</span>. University of Arizona College of Optical Sciences<span class="reference-accessdate">. Retrieved <span class="nowrap">30 March</span> 2012</span>.</cite></span>
</li>
<li id="cite_note-Hariharan2007-5"><span class="mw-cite-backlink"><b><a href="#cite_ref-Hariharan2007_5-0">^</a></b></span> <span class="reference-text"><cite id="CITEREFHariharan2007" class="citation book cs1">Hariharan, P. (2007). <i>Basics of Interferometry, 2nd edition</i>. Elsevier. p. 19. <a href="ISBN_(identifier)" class="mw-redirect" title="ISBN (identifier)">ISBN</a> <bdi>978-0-12-373589-8</bdi>.</cite></span>
</li>
<li id="cite_note-Anderson1994-6"><span class="mw-cite-backlink">^ <a href="#cite_ref-Anderson1994_6-0"><sup><i><b>a</b></i></sup></a> <a href="#cite_ref-Anderson1994_6-1"><sup><i><b>b</b></i></sup></a></span> <span class="reference-text"><cite id="CITEREFAndersonBilger,_H._R.Stedman,_G._E.1994" class="citation journal cs1">Anderson, R.; Bilger, H. R.; Stedman, G. E. (1994). <a rel="nofollow" class="external text" href="http://signallake.com/innovation/andersonNov94.pdf">""Sagnac effect" A century of Earth-rotated interferometers"</a> <span class="cs1-format">(PDF)</span>. <i>Am. J. Phys</i>. <b>62</b> (11): <span class="nowrap">975–</span>985. <a href="Bibcode_(identifier)" class="mw-redirect" title="Bibcode (identifier)">Bibcode</a>:<a rel="nofollow" class="external text" href="https://ui.adsabs.harvard.edu/abs/1994AmJPh..62..975A">1994AmJPh..62..975A</a>. <a href="Doi_(identifier)" class="mw-redirect" title="Doi (identifier)">doi</a>:<a rel="nofollow" class="external text" href="https://doi.org/10.1119%2F1.17656">10.1119/1.17656</a><span class="reference-accessdate">. Retrieved <span class="nowrap">30 March</span> 2012</span>.</cite></span>
</li>
<li id="cite_note-Lin1979-7"><span class="mw-cite-backlink"><b><a href="#cite_ref-Lin1979_7-0">^</a></b></span> <span class="reference-text"><cite id="CITEREFLinGiallorenzi1979" class="citation journal cs1">Lin, S. C.; Giallorenzi, T. G. (1979). "Sensitivity analysis of the Sagnac-effect optical-fiber ring interferometer". <i>Applied Optics</i>. <b>18</b> (6): <span class="nowrap">915–</span>931. <a href="Bibcode_(identifier)" class="mw-redirect" title="Bibcode (identifier)">Bibcode</a>:<a rel="nofollow" class="external text" href="https://ui.adsabs.harvard.edu/abs/1979ApOpt..18..915L">1979ApOpt..18..915L</a>. <a href="Doi_(identifier)" class="mw-redirect" title="Doi (identifier)">doi</a>:<a rel="nofollow" class="external text" href="https://doi.org/10.1364%2FAO.18.000915">10.1364/AO.18.000915</a>. <a href="PMID_(identifier)" class="mw-redirect" title="PMID (identifier)">PMID</a> <a rel="nofollow" class="external text" href="https://pubmed.ncbi.nlm.nih.gov/20208844">20208844</a>.</cite></span>
</li>
<li id="cite_note-mich-8"><span class="mw-cite-backlink"><b><a href="#cite_ref-mich_8-0">^</a></b></span> <span class="reference-text"><cite id="CITEREFMichelson,_A._A.Morley,_E._W.1886" class="citation journal cs1">Michelson, A. A.; Morley, E. W. (1886). <a rel="nofollow" class="external text" href="https://zenodo.org/record/1450072">"Influence of Motion of the Medium on the Velocity of Light"</a>. <i>Am. J. Sci</i>. <b>31</b> (185): <span class="nowrap">377–</span>386. <a href="Bibcode_(identifier)" class="mw-redirect" title="Bibcode (identifier)">Bibcode</a>:<a rel="nofollow" class="external text" href="https://ui.adsabs.harvard.edu/abs/1886AmJS...31..377M">1886AmJS...31..377M</a>. <a href="Doi_(identifier)" class="mw-redirect" title="Doi (identifier)">doi</a>:<a rel="nofollow" class="external text" href="https://doi.org/10.2475%2Fajs.s3-31.185.377">10.2475/ajs.s3-31.185.377</a>. <a href="S2CID_(identifier)" class="mw-redirect" title="S2CID (identifier)">S2CID</a> <a rel="nofollow" class="external text" href="https://api.semanticscholar.org/CorpusID:131116577">131116577</a>.</cite></span>
</li>
<li id="cite_note-ham-9"><span class="mw-cite-backlink"><b><a href="#cite_ref-ham_9-0">^</a></b></span> <span class="reference-text"><cite id="CITEREFG._W._Hammar1935" class="citation journal cs1">G. W. Hammar (1935). "The Velocity of Light Within a Massive Enclosure". <i><a href="Physical_Review" title="Physical Review">Physical Review</a></i>. <b>48</b> (5): <span class="nowrap">462–</span>463. <a href="Bibcode_(identifier)" class="mw-redirect" title="Bibcode (identifier)">Bibcode</a>:<a rel="nofollow" class="external text" href="https://ui.adsabs.harvard.edu/abs/1935PhRv...48..462H">1935PhRv...48..462H</a>. <a href="Doi_(identifier)" class="mw-redirect" title="Doi (identifier)">doi</a>:<a rel="nofollow" class="external text" href="https://doi.org/10.1103%2FPhysRev.48.462.2">10.1103/PhysRev.48.462.2</a>.</cite></span>
</li>
<li id="cite_note-rob-10"><span class="mw-cite-backlink"><b><a href="#cite_ref-rob_10-0">^</a></b></span> <span class="reference-text"><cite id="CITEREFH._P._RobertsonThomas_W._Noonan1968" class="citation book cs1">H. P. Robertson; Thomas W. Noonan (1968). "Hammar's experiment". <span class="id-lock-limited" title="Free access subject to limited trial, subscription normally required"><a rel="nofollow" class="external text" href="https://archive.org/details/relativitycosmol00robe"><i>Relativity and Cosmology</i></a></span>. Philadelphia: Saunders. pp. <a rel="nofollow" class="external text" href="https://archive.org/details/relativitycosmol00robe/page/36">36</a>–38.</cite></span>
</li>
<li id="cite_note-Millerd2004-11"><span class="mw-cite-backlink"><b><a href="#cite_ref-Millerd2004_11-0">^</a></b></span> <span class="reference-text"><cite id="CITEREFMillerdBrock,_N._J.Hayes,_J._B.Wyant,_J._C.2004" class="citation journal cs1">Millerd, J. E.; Brock, N. J.; Hayes, J. B.; Wyant, J. C. (2004). Creath, Katherine; Schmit, Joanna (eds.). <a rel="nofollow" class="external text" href="https://web.archive.org/web/20101008174420/http://www.optics.arizona.edu/jcwyant/pdf/Published_Papers/Phase_Shifting/InstantaneousPhase-shiftPoint-diffractionInterferometer.pdf">"Instantaneous phase-shift, point-diffraction interferometer"</a> <span class="cs1-format">(PDF)</span>. <i>Proceedings of SPIE</i>. Interferometry XII: Techniques and Analysis. <b>5531</b>: <span class="nowrap">264–</span>272. <a href="Bibcode_(identifier)" class="mw-redirect" title="Bibcode (identifier)">Bibcode</a>:<a rel="nofollow" class="external text" href="https://ui.adsabs.harvard.edu/abs/2004SPIE.5531..264M">2004SPIE.5531..264M</a>. <a href="Doi_(identifier)" class="mw-redirect" title="Doi (identifier)">doi</a>:<a rel="nofollow" class="external text" href="https://doi.org/10.1117%2F12.560959">10.1117/12.560959</a>. <a href="S2CID_(identifier)" class="mw-redirect" title="S2CID (identifier)">S2CID</a> <a rel="nofollow" class="external text" href="https://api.semanticscholar.org/CorpusID:125388913">125388913</a>. Archived from <a rel="nofollow" class="external text" href="http://www.optics.arizona.edu/jcwyant/pdf/Published_Papers/Phase_Shifting/InstantaneousPhase-shiftPoint-diffractionInterferometer.pdf">the original</a> <span class="cs1-format">(PDF)</span> on 8 October 2010<span class="reference-accessdate">. Retrieved <span class="nowrap">31 March</span> 2012</span>.</cite></span>
</li>
<li id="cite_note-Mercer1996-12"><span class="mw-cite-backlink"><b><a href="#cite_ref-Mercer1996_12-0">^</a></b></span> <span class="reference-text"><cite id="CITEREFMercerRashidnia,_N.Creath,_K.1996" class="citation journal cs1">Mercer, C. R.; Rashidnia, N.; Creath, K. (1996). <a rel="nofollow" class="external text" href="https://ntrs.nasa.gov/archive/nasa/casi.ntrs.nasa.gov/19960033183_1996063135.pdf">"High data density temperature measurement for quasi steady-state flows"</a> <span class="cs1-format">(PDF)</span>. <i>Experiments in Fluids</i>. <b>21</b> (1): <span class="nowrap">11–</span>16. <a href="Bibcode_(identifier)" class="mw-redirect" title="Bibcode (identifier)">Bibcode</a>:<a rel="nofollow" class="external text" href="https://ui.adsabs.harvard.edu/abs/1996ExFl...21...11M">1996ExFl...21...11M</a>. <a href="Doi_(identifier)" class="mw-redirect" title="Doi (identifier)">doi</a>:<a rel="nofollow" class="external text" href="https://doi.org/10.1007%2FBF00204630">10.1007/BF00204630</a>. <a href="Hdl_(identifier)" class="mw-redirect" title="Hdl (identifier)">hdl</a>:<span class="id-lock-free" title="Freely accessible"><a rel="nofollow" class="external text" href="https://hdl.handle.net/2060%2F19960033183">2060/19960033183</a></span>. <a href="S2CID_(identifier)" class="mw-redirect" title="S2CID (identifier)">S2CID</a> <a rel="nofollow" class="external text" href="https://api.semanticscholar.org/CorpusID:55927553">55927553</a><span class="reference-accessdate">. Retrieved <span class="nowrap">31 March</span> 2012</span>.</cite></span>
</li>
<li id="cite_note-Ferraro2007-13"><span class="mw-cite-backlink"><b><a href="#cite_ref-Ferraro2007_13-0">^</a></b></span> <span class="reference-text"><cite id="CITEREFFerraro2007" class="citation web cs1">Ferraro, P.; Paturzo, M.; Grilli, S. (2007). <a rel="nofollow" class="external text" href="http://spie.org/x8369.xml">"Optical wavefront measurement using a novel phase-shifting point-diffraction interferometer"</a>. SPIE<span class="reference-accessdate">. Retrieved <span class="nowrap">26 May</span> 2012</span>.</cite><span class="cs1-maint citation-comment"><code class="cs1-code">{{cite web}}</code>: CS1 maint: multiple names: authors list (link)</span></span>
</li>
<li id="cite_note-Naulleau1999-14"><span class="mw-cite-backlink"><b><a href="#cite_ref-Naulleau1999_14-0">^</a></b></span> <span class="reference-text"><cite id="CITEREFNaulleauGoldbergLeeChang1999" class="citation journal cs1">Naulleau, P. P.; Goldberg, K. A.; Lee, S. H.; Chang, C.; Attwood, D.; Bokor, J. (1999). "Extreme-ultraviolet phase-shifting point-diffraction interferometer: A wave-front metrology tool with subangstrom reference-wave accuracy". <i>Applied Optics</i>. <b>38</b> (35): <span class="nowrap">7252–</span>7263. <a href="Bibcode_(identifier)" class="mw-redirect" title="Bibcode (identifier)">Bibcode</a>:<a rel="nofollow" class="external text" href="https://ui.adsabs.harvard.edu/abs/1999ApOpt..38.7252N">1999ApOpt..38.7252N</a>. <a href="Doi_(identifier)" class="mw-redirect" title="Doi (identifier)">doi</a>:<a rel="nofollow" class="external text" href="https://doi.org/10.1364%2FAO.38.007252">10.1364/AO.38.007252</a>. <a href="PMID_(identifier)" class="mw-redirect" title="PMID (identifier)">PMID</a> <a rel="nofollow" class="external text" href="https://pubmed.ncbi.nlm.nih.gov/18324274">18324274</a>.</cite></span>
</li>
<li id="cite_note-Malacara2006-15"><span class="mw-cite-backlink">^ <a href="#cite_ref-Malacara2006_15-0"><sup><i><b>a</b></i></sup></a> <a href="#cite_ref-Malacara2006_15-1"><sup><i><b>b</b></i></sup></a> <a href="#cite_ref-Malacara2006_15-2"><sup><i><b>c</b></i></sup></a></span> <span class="reference-text"><cite id="CITEREFMallickMalacara2007" class="citation book cs1">Mallick, S.; Malacara, D. (2007). "Common-Path Interferometers". <i>Optical Shop Testing</i>. p. 97. <a href="Doi_(identifier)" class="mw-redirect" title="Doi (identifier)">doi</a>:<a rel="nofollow" class="external text" href="https://doi.org/10.1002%2F9780470135976.ch3">10.1002/9780470135976.ch3</a>. <a href="ISBN_(identifier)" class="mw-redirect" title="ISBN (identifier)">ISBN</a> <bdi>9780470135976</bdi>.</cite></span>
</li>
<li id="cite_note-Love1995-16"><span class="mw-cite-backlink"><b><a href="#cite_ref-Love1995_16-0">^</a></b></span> <span class="reference-text"><cite id="CITEREFLoveAndrews,_N.Birch,_P.Buscher,_D.1995" class="citation journal cs1">Love, G. D.; Andrews, N.; Birch, P.; Buscher, D.; Doel, P.; Dunlop, C.; Major, J.; Myers, R.; Purvis, A.; Sharples, R.; Vick, A.; Zadrozny, A.; Restaino, S. R.; Glindemann, A. (1995). <a rel="nofollow" class="external text" href="https://web.archive.org/web/20121107000706/http://www.dur.ac.uk/g.d.love/downloadable/p011Binary_adapt_optics.pdf">"Binary adaptive optics: atmospheric wave-front correction with a half-wave phase shifter"</a> <span class="cs1-format">(PDF)</span>. <i>Applied Optics</i>. <b>34</b> (27): <span class="nowrap">6058–</span>6066. <a href="Bibcode_(identifier)" class="mw-redirect" title="Bibcode (identifier)">Bibcode</a>:<a rel="nofollow" class="external text" href="https://ui.adsabs.harvard.edu/abs/1995ApOpt..34.6058L">1995ApOpt..34.6058L</a>. <a href="Doi_(identifier)" class="mw-redirect" title="Doi (identifier)">doi</a>:<a rel="nofollow" class="external text" href="https://doi.org/10.1364%2FAO.34.006058">10.1364/AO.34.006058</a>. <a href="PMID_(identifier)" class="mw-redirect" title="PMID (identifier)">PMID</a> <a rel="nofollow" class="external text" href="https://pubmed.ncbi.nlm.nih.gov/21060444">21060444</a>. Archived from <a rel="nofollow" class="external text" href="http://www.dur.ac.uk/g.d.love/downloadable/p011Binary_adapt_optics.pdf">the original</a> <span class="cs1-format">(PDF)</span> on 7 November 2012<span class="reference-accessdate">. Retrieved <span class="nowrap">31 March</span> 2012</span>.</cite></span>
</li>
<li id="cite_note-Paterson2007-17"><span class="mw-cite-backlink"><b><a href="#cite_ref-Paterson2007_17-0">^</a></b></span> <span class="reference-text"><cite id="CITEREFPatersonNotaras2007" class="citation journal cs1">Paterson, C.; Notaras, J. (2007). <a rel="nofollow" class="external text" href="https://doi.org/10.1364%2FOE.15.013745">"Demonstration of closed-loop adaptive optics with a point-diffraction interferometer in strong scintillation with optical vortices"</a>. <i>Optics Express</i>. <b>15</b> (21): <span class="nowrap">13745–</span>13756. <a href="Bibcode_(identifier)" class="mw-redirect" title="Bibcode (identifier)">Bibcode</a>:<a rel="nofollow" class="external text" href="https://ui.adsabs.harvard.edu/abs/2007OExpr..1513745P">2007OExpr..1513745P</a>. <a href="Doi_(identifier)" class="mw-redirect" title="Doi (identifier)">doi</a>:<span class="id-lock-free" title="Freely accessible"><a rel="nofollow" class="external text" href="https://doi.org/10.1364%2FOE.15.013745">10.1364/OE.15.013745</a></span>. <a href="PMID_(identifier)" class="mw-redirect" title="PMID (identifier)">PMID</a> <a rel="nofollow" class="external text" href="https://pubmed.ncbi.nlm.nih.gov/19550645">19550645</a>.</cite></span>
</li>
<li id="cite_note-Strojnik2006-18"><span class="mw-cite-backlink"><b><a href="#cite_ref-Strojnik2006_18-0">^</a></b></span> <span class="reference-text"><cite id="CITEREFStrojnikPaezMantravadi2007" class="citation book cs1">Strojnik, M.; Paez, G.; Mantravadi, M. (2007). "Lateral Shear Interferometers". <i>Optical Shop Testing</i>. p. 122. <a href="Doi_(identifier)" class="mw-redirect" title="Doi (identifier)">doi</a>:<a rel="nofollow" class="external text" href="https://doi.org/10.1002%2F9780470135976.ch4">10.1002/9780470135976.ch4</a>. <a href="ISBN_(identifier)" class="mw-redirect" title="ISBN (identifier)">ISBN</a> <bdi>9780470135976</bdi>.</cite></span>
</li>
<li id="cite_note-19"><span class="mw-cite-backlink"><b><a href="#cite_ref-19">^</a></b></span> <span class="reference-text"><cite id="CITEREFChanteloup2005" class="citation journal cs1">Chanteloup, J. C. (2005). "Multiple-wave lateral shearing interferometry for wave-front sensing". <i>Applied Optics</i>. <b>44</b> (9): <span class="nowrap">1559–</span>1571. <a href="Bibcode_(identifier)" class="mw-redirect" title="Bibcode (identifier)">Bibcode</a>:<a rel="nofollow" class="external text" href="https://ui.adsabs.harvard.edu/abs/2005ApOpt..44.1559C">2005ApOpt..44.1559C</a>. <a href="Doi_(identifier)" class="mw-redirect" title="Doi (identifier)">doi</a>:<a rel="nofollow" class="external text" href="https://doi.org/10.1364%2FAO.44.001559">10.1364/AO.44.001559</a>. <a href="PMID_(identifier)" class="mw-redirect" title="PMID (identifier)">PMID</a> <a rel="nofollow" class="external text" href="https://pubmed.ncbi.nlm.nih.gov/15818859">15818859</a>.</cite></span>
</li>
<li id="cite_note-Ribak-20"><span class="mw-cite-backlink"><b><a href="#cite_ref-Ribak_20-0">^</a></b></span> <span class="reference-text"><cite id="CITEREFRibak" class="citation web cs1">Ribak, E.N. <a rel="nofollow" class="external text" href="https://web.archive.org/web/20130225133243/http://physics.technion.ac.il/~eribak/GlasgowAOInt.pdf">"Interferometry following adaptive optics"</a> <span class="cs1-format">(PDF)</span>. Archived from <a rel="nofollow" class="external text" href="http://physics.technion.ac.il/~eribak/GlasgowAOInt.pdf">the original</a> <span class="cs1-format">(PDF)</span> on 25 February 2013<span class="reference-accessdate">. Retrieved <span class="nowrap">14 April</span> 2012</span>.</cite></span>
</li>
<li id="cite_note-21"><span class="mw-cite-backlink"><b><a href="#cite_ref-21">^</a></b></span> <span class="reference-text"><cite id="CITEREFPrimot" class="citation web cs1">Primot, J.; Guernineau, N. <a rel="nofollow" class="external text" href="https://web.archive.org/web/20120303055516/http://www.master-optics.eu/biblio/primot_guerineau.pdf">"Shearing interferometry for wavefront sensing"</a> <span class="cs1-format">(PDF)</span>. OpSciTech. Archived from <a rel="nofollow" class="external text" href="http://www.master-optics.eu/biblio/primot_guerineau.pdf">the original</a> <span class="cs1-format">(PDF)</span> on 2012-03-03<span class="reference-accessdate">. Retrieved <span class="nowrap">2012-04-15</span></span>.</cite><span class="cs1-maint citation-comment"><code class="cs1-code">{{cite web}}</code>: CS1 maint: multiple names: authors list (link)</span></span>
</li>
<li id="cite_note-NewtonOpticks-22"><span class="mw-cite-backlink"><b><a href="#cite_ref-NewtonOpticks_22-0">^</a></b></span> <span class="reference-text"><cite id="CITEREFNewton1730" class="citation book cs1">Newton, Isaac (1730). <a rel="nofollow" class="external text" href="http://www.gutenberg.org/files/33504/33504-h/33504-h.htm"><i>Opticks: or, a Treatise of the Reflections, Refractions, Inflections and Colours of Light</i></a>. Project Gutenberg. pp. <span class="nowrap">317–</span>406.</cite></span>
</li>
<li id="cite_note-23"><span class="mw-cite-backlink"><b><a href="#cite_ref-23">^</a></b></span> <span class="reference-text">M. Lehmann, H. Lichte, Tutorial on off-axis electron holography, Microsc. Microanal. 8(6), 447–466 (2002)</span>
</li>
<li id="cite_note-Tonomura1999-24"><span class="mw-cite-backlink"><b><a href="#cite_ref-Tonomura1999_24-0">^</a></b></span> <span class="reference-text"><cite id="CITEREFTonomura1999" class="citation book cs1">Tonomura, A. (1999). <a rel="nofollow" class="external text" href="https://books.google.com/books?id=ghn_GeKbRo0C"><i>Electron Holography, 2nd ed</i></a>. Springer. <a href="ISBN_(identifier)" class="mw-redirect" title="ISBN (identifier)">ISBN</a> <bdi>3540645551</bdi>.</cite></span>
</li>
<li id="cite_note-Sun1996-25"><span class="mw-cite-backlink"><b><a href="#cite_ref-Sun1996_25-0">^</a></b></span> <span class="reference-text"><cite id="CITEREFSunFejer,_M._M.Gustafson,_E.Byer_R._L.1996" class="citation journal cs1">Sun, K.-X.; Fejer, M. M.; Gustafson, E.; Byer R. L. (1996). <a rel="nofollow" class="external text" href="https://nlo.stanford.edu/fejerpubs/1996/93.pdf">"Sagnac Interferometer for Gravitational-Wave Detection"</a> <span class="cs1-format">(PDF)</span>. <i>Physical Review Letters</i>. <b>76</b> (17): <span class="nowrap">3053–</span>3056. <a href="Bibcode_(identifier)" class="mw-redirect" title="Bibcode (identifier)">Bibcode</a>:<a rel="nofollow" class="external text" href="https://ui.adsabs.harvard.edu/abs/1996PhRvL..76.3053S">1996PhRvL..76.3053S</a>. <a href="Doi_(identifier)" class="mw-redirect" title="Doi (identifier)">doi</a>:<a rel="nofollow" class="external text" href="https://doi.org/10.1103%2FPhysRevLett.76.3053">10.1103/PhysRevLett.76.3053</a>. <a href="PMID_(identifier)" class="mw-redirect" title="PMID (identifier)">PMID</a> <a rel="nofollow" class="external text" href="https://pubmed.ncbi.nlm.nih.gov/10060864">10060864</a><span class="reference-accessdate">. Retrieved <span class="nowrap">31 March</span> 2012</span>.</cite></span>
</li>
<li id="cite_note-Friese2009-26"><span class="mw-cite-backlink"><b><a href="#cite_ref-Friese2009_26-0">^</a></b></span> <span class="reference-text"><cite id="CITEREFFreiseChelkowskiHildPozzo2009" class="citation journal cs1">Freise, A.; Chelkowski, S.; Hild, S.; Pozzo, W. D.; Perreca, A.; Vecchio, A. (2009). "Triple Michelson interferometer for a third-generation gravitational wave detector". <i>Classical and Quantum Gravity</i>. <b>26</b> (8): 085012. <a href="ArXiv_(identifier)" class="mw-redirect" title="ArXiv (identifier)">arXiv</a>:<span class="id-lock-free" title="Freely accessible"><a rel="nofollow" class="external text" href="https://arxiv.org/abs/0804.1036">0804.1036</a></span>. <a href="Bibcode_(identifier)" class="mw-redirect" title="Bibcode (identifier)">Bibcode</a>:<a rel="nofollow" class="external text" href="https://ui.adsabs.harvard.edu/abs/2009CQGra..26h5012F">2009CQGra..26h5012F</a>. <a href="Doi_(identifier)" class="mw-redirect" title="Doi (identifier)">doi</a>:<a rel="nofollow" class="external text" href="https://doi.org/10.1088%2F0264-9381%2F26%2F8%2F085012">10.1088/0264-9381/26/8/085012</a>. <a href="S2CID_(identifier)" class="mw-redirect" title="S2CID (identifier)">S2CID</a> <a rel="nofollow" class="external text" href="https://api.semanticscholar.org/CorpusID:7535227">7535227</a>.</cite></span>
</li>
<li id="cite_note-Eberle2010-27"><span class="mw-cite-backlink"><b><a href="#cite_ref-Eberle2010_27-0">^</a></b></span> <span class="reference-text"><cite id="CITEREFEberleSteinlechnerBauchrowitzHändchen2010" class="citation journal cs1">Eberle, T.; Steinlechner, S.; Bauchrowitz, J. R.; Händchen, V.; Vahlbruch, H.; Mehmet, M.; Müller-Ebhardt, H.; Schnabel, R. (2010). "Quantum Enhancement of the Zero-Area Sagnac Interferometer Topology for Gravitational Wave Detection". <i>Physical Review Letters</i>. <b>104</b> (25): 251102. <a href="ArXiv_(identifier)" class="mw-redirect" title="ArXiv (identifier)">arXiv</a>:<span class="id-lock-free" title="Freely accessible"><a rel="nofollow" class="external text" href="https://arxiv.org/abs/1007.0574">1007.0574</a></span>. <a href="Bibcode_(identifier)" class="mw-redirect" title="Bibcode (identifier)">Bibcode</a>:<a rel="nofollow" class="external text" href="https://ui.adsabs.harvard.edu/abs/2010PhRvL.104y1102E">2010PhRvL.104y1102E</a>. <a href="Doi_(identifier)" class="mw-redirect" title="Doi (identifier)">doi</a>:<a rel="nofollow" class="external text" href="https://doi.org/10.1103%2FPhysRevLett.104.251102">10.1103/PhysRevLett.104.251102</a>. <a href="PMID_(identifier)" class="mw-redirect" title="PMID (identifier)">PMID</a> <a rel="nofollow" class="external text" href="https://pubmed.ncbi.nlm.nih.gov/20867358">20867358</a>. <a href="S2CID_(identifier)" class="mw-redirect" title="S2CID (identifier)">S2CID</a> <a rel="nofollow" class="external text" href="https://api.semanticscholar.org/CorpusID:9929939">9929939</a>.</cite></span>
</li>
<li id="cite_note-UACOS-28"><span class="mw-cite-backlink">^ <a href="#cite_ref-UACOS_28-0"><sup><i><b>a</b></i></sup></a> <a href="#cite_ref-UACOS_28-1"><sup><i><b>b</b></i></sup></a></span> <span class="reference-text"><cite class="citation web cs1"><a rel="nofollow" class="external text" href="https://web.archive.org/web/20100725064530/http://www.optics.arizona.edu/jcwyant/Short_Courses/SIRA/6-TestingCurvedSurfaces.pdf">"Testing Curved Surfaces and Lenses"</a> <span class="cs1-format">(PDF)</span>. University of Arizona College of Optical Sciences. Archived from <a rel="nofollow" class="external text" href="http://www.optics.arizona.edu/jcwyant/Short_Courses/SIRA/6-TestingCurvedSurfaces.pdf">the original</a> <span class="cs1-format">(PDF)</span> on 25 July 2010<span class="reference-accessdate">. Retrieved <span class="nowrap">30 March</span> 2012</span>.</cite></span>
</li>
<li id="cite_note-Burch1953-29"><span class="mw-cite-backlink"><b><a href="#cite_ref-Burch1953_29-0">^</a></b></span> <span class="reference-text"><cite id="CITEREFBurch1953" class="citation journal cs1">Burch, J. M. (1953). "Scatter fringes of equal thickness". <i>Nature</i>. <b>171</b> (4359): <span class="nowrap">889–</span>890. <a href="Bibcode_(identifier)" class="mw-redirect" title="Bibcode (identifier)">Bibcode</a>:<a rel="nofollow" class="external text" href="https://ui.adsabs.harvard.edu/abs/1953Natur.171..889B">1953Natur.171..889B</a>. <a href="Doi_(identifier)" class="mw-redirect" title="Doi (identifier)">doi</a>:<a rel="nofollow" class="external text" href="https://doi.org/10.1038%2F171889a0">10.1038/171889a0</a>. <a href="S2CID_(identifier)" class="mw-redirect" title="S2CID (identifier)">S2CID</a> <a rel="nofollow" class="external text" href="https://api.semanticscholar.org/CorpusID:24650839">24650839</a>.</cite></span>
</li>
<li id="cite_note-SPIETwymanGreen-30"><span class="mw-cite-backlink"><b><a href="#cite_ref-SPIETwymanGreen_30-0">^</a></b></span> <span class="reference-text"><cite class="citation web cs1"><a rel="nofollow" class="external text" href="http://spie.org/x32483.xml">"Twyman-Green Interferometer"</a>. SPIE<span class="reference-accessdate">. Retrieved <span class="nowrap">30 March</span> 2012</span>.</cite></span>
</li>
<li id="cite_note-Optics4EngineersTwyman-31"><span class="mw-cite-backlink"><b><a href="#cite_ref-Optics4EngineersTwyman_31-0">^</a></b></span> <span class="reference-text"><cite class="citation web cs1"><a rel="nofollow" class="external text" href="http://www.optique-ingenieur.org/en/courses/OPI_ang_M02_C05/co/Contenu_31.html">"Twyman-Green Interferometer"</a>. Optics 4 Engineers<span class="reference-accessdate">. Retrieved <span class="nowrap">30 March</span> 2012</span>.</cite></span>
</li>
<li id="cite_note-Dyson1957-32"><span class="mw-cite-backlink"><b><a href="#cite_ref-Dyson1957_32-0">^</a></b></span> <span class="reference-text"><cite id="CITEREFDyson1957" class="citation journal cs1">Dyson, J. (1957). "Common-Path Interferometer for Testing Purposes". <i>Journal of the Optical Society of America</i>. <b>47</b> (5): <span class="nowrap">386–</span>387. <a href="Bibcode_(identifier)" class="mw-redirect" title="Bibcode (identifier)">Bibcode</a>:<a rel="nofollow" class="external text" href="https://ui.adsabs.harvard.edu/abs/1957JOSA...47..386D">1957JOSA...47..386D</a>. <a href="Doi_(identifier)" class="mw-redirect" title="Doi (identifier)">doi</a>:<a rel="nofollow" class="external text" href="https://doi.org/10.1364%2Fjosa.47.000386">10.1364/josa.47.000386</a>.</cite></span>
</li>
<li id="cite_note-Wyatt2002-33"><span class="mw-cite-backlink"><b><a href="#cite_ref-Wyatt2002_33-0">^</a></b></span> <span class="reference-text"><cite id="CITEREFWyant2002" class="citation journal cs1">Wyant, J.C. (2002). <a rel="nofollow" class="external text" href="https://web.archive.org/web/20060906064907/http://www.optics.arizona.edu/jcwyant/pdf/Published_Papers/Optical_Testing/WhiteLightInterferometry.pdf">"White Light Interferometry"</a> <span class="cs1-format">(PDF)</span>. <i>Proceedings of SPIE</i>. <b>4737</b>: <span class="nowrap">98–</span>107. <a href="Bibcode_(identifier)" class="mw-redirect" title="Bibcode (identifier)">Bibcode</a>:<a rel="nofollow" class="external text" href="https://ui.adsabs.harvard.edu/abs/2002SPIE.4737...98W">2002SPIE.4737...98W</a>. <a href="Doi_(identifier)" class="mw-redirect" title="Doi (identifier)">doi</a>:<a rel="nofollow" class="external text" href="https://doi.org/10.1117%2F12.474947">10.1117/12.474947</a>. <a href="S2CID_(identifier)" class="mw-redirect" title="S2CID (identifier)">S2CID</a> <a rel="nofollow" class="external text" href="https://api.semanticscholar.org/CorpusID:123532345">123532345</a>. Archived from <a rel="nofollow" class="external text" href="http://www.optics.arizona.edu/jcwyant/pdf/Published_Papers/Optical_Testing/WhiteLightInterferometry.pdf">the original</a> <span class="cs1-format">(PDF)</span> on 6 September 2006<span class="reference-accessdate">. Retrieved <span class="nowrap">30 March</span> 2012</span>.</cite></span>
</li>
<li id="cite_note-34"><span class="mw-cite-backlink"><b><a href="#cite_ref-34">^</a></b></span> <span class="reference-text"><style data-mw-deduplicate="TemplateStyles:r1041539562">
/* start https://en.wikipedia.org/ */
.mw-parser-output .citation{word-wrap:break-word}.mw-parser-output .citation:target{background-color:rgba(0,127,255,0.133)}
/* end https://en.wikipedia.org/ */
</style><span class="citation patent" id="CITEREFKarl-Ludwig_Bath"><a rel="nofollow" class="external text" href="https://patents.google.com/patent/DE2300958A1/en?oq=de2300958">DE patent 2300958</a>, Karl-Ludwig Bath, "Ein Interferometer mit gemeinsamem Weg für Referenzstrahl und messtrahl (common path interferometer)", published 1974-07-01</span><span class="Z3988" title="ctx_ver=Z39.88-2004&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Apatent&rft.number=2300958&rft.cc=DE&rft.title=Ein+Interferometer+mit+gemeinsamem+Weg+f%C3%BCr+Referenzstrahl+und+messtrahl+%28common+path+interferometer%29&rft.inventor=Karl-Ludwig+Bath&rft.appldate=1974-01-10&rft.pubdate=1974-07-01"><span style="display: none;"> </span></span></span>
</li>
<li id="cite_note-Mico2006-35"><span class="mw-cite-backlink"><b><a href="#cite_ref-Mico2006_35-0">^</a></b></span> <span class="reference-text"><cite id="CITEREFMicoZalefsky,_ZGarcia,_J.2006" class="citation journal cs1">Mico, V.; Zalefsky, Z; Garcia, J. (2006). <a rel="nofollow" class="external text" href="http://www.uv.es/~gpoei/articulos/(2006)%20OEX%2014%20(12)%20Superresolution%20optical%20system%20by%20common-path%20interferometry.pdf">"Superresolution optical system by common-path interferometry"</a> <span class="cs1-format">(PDF)</span>. <i>Optics Express</i>. <b>14</b> (12): <span class="nowrap">5168–</span>5177. <a href="Bibcode_(identifier)" class="mw-redirect" title="Bibcode (identifier)">Bibcode</a>:<a rel="nofollow" class="external text" href="https://ui.adsabs.harvard.edu/abs/2006OExpr..14.5168M">2006OExpr..14.5168M</a>. <a href="Doi_(identifier)" class="mw-redirect" title="Doi (identifier)">doi</a>:<span class="id-lock-free" title="Freely accessible"><a rel="nofollow" class="external text" href="https://doi.org/10.1364%2Foe.14.005168">10.1364/oe.14.005168</a></span>. <a href="PMID_(identifier)" class="mw-redirect" title="PMID (identifier)">PMID</a> <a rel="nofollow" class="external text" href="https://pubmed.ncbi.nlm.nih.gov/19516681">19516681</a><span class="reference-accessdate">. Retrieved <span class="nowrap">31 March</span> 2012</span>.</cite></span>
</li>
<li id="cite_note-Márquez2001-36"><span class="mw-cite-backlink"><b><a href="#cite_ref-Márquez2001_36-0">^</a></b></span> <span class="reference-text"><cite id="CITEREFMárquezYamauchiDavisFranich2001" class="citation journal cs1">Márquez, A. S.; Yamauchi, M.; Davis, J. A.; Franich, D. J. (2001). "Phase measurements of a twisted nematic liquid crystal spatial light modulator with a common-path interferometer". <i>Optics Communications</i>. <b>190</b> (<span class="nowrap">1–</span>6): <span class="nowrap">129–</span>133. <a href="Bibcode_(identifier)" class="mw-redirect" title="Bibcode (identifier)">Bibcode</a>:<a rel="nofollow" class="external text" href="https://ui.adsabs.harvard.edu/abs/2001OptCo.190..129M">2001OptCo.190..129M</a>. <a href="Doi_(identifier)" class="mw-redirect" title="Doi (identifier)">doi</a>:<a rel="nofollow" class="external text" href="https://doi.org/10.1016%2FS0030-4018%2801%2901091-4">10.1016/S0030-4018(01)01091-4</a>.</cite></span>
</li>
</ol></div></div></div><!--htdig_noindex--><div><div class="zim-footer">
This article is issued from <a class="external text" title="Last edited on 2023-12-18" href="https://en.wikipedia.org/wiki/?title=Common-path_interferometer&oldid=1190592132">Wikipedia</a>. The text is available under <a class="external text" href="https://creativecommons.org/licenses/by-sa/4.0/deed.en">Creative Commons Attribution-Share Alike 4.0</a> unless otherwise noted. Additional terms may apply for the media files.
</div>
</div><!--/htdig_noindex--></div>
</div>
</main>
</div>
</div>
</div>
</body></html>